NIOSH Issues Safety Advisory for Aerial Ladders With Locking Waterway

The National Institute for Occupational Safety and Health (NIOSH) has issued a safety advisory regarding the set-up of aerial ladders with a locking waterway. NIOSH is currently investigating an April 8, 2008, fire fighter line-of-duty-death involving an aerial ladder with a locking waterway. This incident highlights the importance of following the manufacturer’s recommendations for aerial ladder operations to ensure the safety of IAFF members.

waterway.jpg

waterway1.jpg

  • Ensure that Standard Operating Procedures (SOPs) and/or Guidelines (SOGs) on setting up multi-position waterways include steps to properly position the waterway and to inspect and verify that the locking mechanism (anchoring pin(s), lever, clamps, etc.) are properly installed and functioning as designed before pressurizing the waterway.

  • Properly train and practice the correct method of securing waterways and verifying they are secured (per manufacturer’s recommendations)
  • Circumstances of incident under investigation by NIOSH
    On April 8, 2008, a volunteer Deputy Fire Chief (the Incident Commander), was killed when struck by a motorized water monitor and 30 feet of aluminum pipe that was “launched” off an elevated aerial ladder at a fire at an industrial manufacturing plant in Pennsylvania. The truck was normally transported in the “rescue mode” with the monitor pinned to the second section of ladder so that the waterway would not be in the way if the ladder was set up for rescue operations. At the incident scene, when the waterway was pressurized, the monitor and its support bracket, along with the last 30-foot section of pipe were “launched” off the aerial ladder by the force of the water pressure in the pipe. The monitor flew approximately 75 feet and fell, striking the Incident Commander on the head, killing him instantly.
    After the incident, the anchor pin was found on the ground, in front of the truck’s cab. The waterway did not include any secondary mechanical stops to prevent the separation of the water monitor in the event the anchoring pin was not properly seated. The NIOSH Fire Fighter Fatality Investigation and Prevention Program is currently investigating this incident and a full report will be available at a later date.
  • NIOSH would like to bring this information to the attention of all U.S. fire departments and fire fighters who operate or work around aerial ladder trucks with locking (pin-anchored, lever actuated, clamped) waterways so that future occurrences of waterway monitor “launches” or the unexpected movement of the waterway monitor can be prevented. If secondary mechanical stops are present, the unexpected impact of the waterway monitor against the mechanical stop could cause structural damage to the aerial ladder and jeopardize the safety of any fire fighter standing on the aerial ladder. While not a contributing factor in the fatal incident, NIOSH reminds fire departments to comply with relevant federal regulations and NFPA standards for fire apparatus inspections and certification.
  • In addition, all fire apparatus, including fire department aerial devices, should be inspected on an annual basis as required by the Occupational Safety and Health Administration (OSHA). In 1910.156 it specifically states that the “employer shall maintain and inspect, at least annually, fire fighting equipment to assure the safe operational condition of the equipment. Fire fighting equipment that is in damaged or unserviceable condition shall be removed from service and replaced.”

    waterway3.jpg

    Further, NFPA 1911 Standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus requires the annual inspection and testing of all fire apparatus, including the aerial device. The complete NIOSH User Notice is available online. http://www.cdc.gov/niosh/fire/SafetyAdvisory05052008.html

    waterway4.jpg

    WestCoast 911 source: IAFF

 